切换
资源分类
文档管理
收藏夹
最新动态
登陆
注册
关闭
返回
下载
相似
相似资源:
长江证券:氢能-顶层、配套政策快速推进,2023年电解槽招标1.61GW以上.pdf
支持气候中和园区发展的数字化工具--中德能源与能效合作.pdf
一次性纸制品生产企业碳中和实施指南.pdf
中国储能市场现状及应用研讨PPT--光伏业协会(1).pdf
团体标准-《低碳社区(近零碳排放社区)建设和评价指南》(征求意见稿).pdf
邮政快递业低碳发展路径研究与策略报告--快递协会.pdf
双碳与可持续发展实用手册-v01.03-20240301-价值前瞻-150页.pdf
头豹:2023年中国工商业储能行业系列报告(上)-峰谷价差拉大,工商业储能需求爆发可期(摘要版).pdf
数字经济-绿色电力+绿色算力协同发展,新市场孵化新业态.pdf
项目案例-光热发电设备开发与迪拜光热光伏项目介绍-43页.pdf
解码中国省级交通领域2012—2019年二氧化碳排放--世界能源研究所.pdf
欧盟新电池法与碳足迹规则PPT - 202308-亿科-23页_OCR.pdf
敏实集团碳中和白皮书.pdf
零碳园区评价通则.pdf
平安证券:绿氢化工项目将如何落地?.pdf
国贸控股集团碳达峰碳中和行动白皮书.pdf
广东省道路交通领域中长期深度减排研究--世界能源研究所.pdf
国联证券:特高压建设加速_海外需求共驱电力设备新成长.pdf
光伏行业政策月报(2024年2月第二期)--光伏行业协会.pdf
国网PPT:分布式光伏并网消纳关键技术及应用实证.pdf
风电行业3月月度报告:海风蓄势待发,二季度有望迎来招标、出货双升-240308-中信建投-28页.pdf
资源描述:
Performance Modeling of the Car-roof PV - OverviewKenji Araki1, Yasuyuki Ota2, and Masafumi Yamaguchi11Toyota Technological Institute, cpvkenjiarakitoyota-ti.ac.jp, Nagoya, Japan2University of Miyazaki, Miyazaki, Japan Testing car-roof PV Three issues Accurate performance measurement in indoor STC Mauro PRAVETTONI et al., SNEC 2019 Scientific ConferenceAccurate product testing STC/SOC Fair modeling in energy yield on the car Durability and safety Scientific contents in today’s presentationTesting a curved PV moduleDevelopment a protocol for repeatable measurementModeling solar irradiance on the car-roofDynamic installationShading influencePartial shading Curved PV is often overestimated. Example of the radius of curvature of the car-roof Reference Accurate performance measurement in indoor STC, Mauro PRAVETTONI et al., SNEC 2019 Scientific ConferencedFor typical solar simulators, the range of the working distance d may be a bigger issue. Curved PV is illuminated in testing out of the aperture areaPin A Irr Pin Input energyA Aperture areaIrr IrradianceRay outside the aperture illuminates the curved PV, and input energy will be underestimated. Overestimation of performance The virtual position of the aperture may be the geometrical gravity of the curve profile. Inconsistency in “area”, projected area vs. total areaFlattened module testedCurvedTotal area area used for testProjected area area for module operation Local cosine loss and self-shading loss are inherent, but enhanced in the outdoor operationThis means testing angular performance is essential to curved PV car-roof PV.Illumination direction in testing Illumination direction in operation Typical illumination of the curved PV in outdoor operation Curve correction factor f1 is the coving factor, or in another way, geometrical curve correction factor corresponding to the ratio of the projected area by surface area, f2 is the irradiance ratio due to the local cosine loss and self-shading loss, in other words, optical curve correction factor. f 3 is the correction of uneven expansion of the curved module. Round-robin of the car-roof PVScope Standard measurement method for the curved car-roof PV panel.PurposeIdentification of the measurement errors in measurement.Improvement of the measurement method by testing labs.PlanOperated by IEC TC82. To be started in April, 2020.We are about to investigate preliminary protocols using flexible Si modules by JET and AIST. https//www.kurumaerabi.com/car_mag/list/6690/ Minimum requirement of the solar simulator 1.0 1.1 1.2 1.3 1.4 1.5Ratio of the width/depth of the uniform illumination area relative to the procected width/depth of the curved PV panel010 203040Angle of divergence deg 2 5 10Contor of the max-min/mean of flux illuminating onto the curved panel BackgroundThe minimum requirement of the solar simulator standard type shown in the last meeting was too strict for testing laboratory equipped with instruments to normal PV modules.RelaxationFlux not irradiance onto the ¼ of Si cell region is less than ± 1 after correction of illumination level at the plane of the center of gravity of the surface.Illuminated Area 10 more module lengthAND Angle of divergence 30° Ultimate solution Collimated solar simulator For more information, visit http//solaraddedvalue.com/en/category/productos/helios-3198/ Mathematical solution by Dr. Tayagaki, AIST The curve correction factor may be approximated byT Tayagaki, K Araki, M Yamaguchi, T Sugaya, IEEE Journal of Photovoltaics 9 6, 1721-1726 Solar irradiation of the car-roof is complicated but can be modeled. Solar resource monitoring around the car-body by University of Miyazaki Why is 5-axis measurement important “One sensor on the car-roof” does not have sufficient DOF to validate the outdoor irradiance model. 3-D evaluation including angular weighting is crucial to the module design. Shading effect locally varies, for example, less shading in y direction than x direction. One sensor monitoring cannot detect such car-specific solar environment. Car-roof PV modelingReference Car-roof Coving factor 0.97Equivalent R 3.5 m Validation of the model - IntensityAnnually MonthlyDaily Validation of the model – Angular distribution 012345678 0 15 30 45 60 75 90Weighted percentage Incident angle deg ModelMeasurement Note Validation was done by the weighted histogram of the incident angle of the main beam. Inherent error is expected to the higher incident angle corresponding overcast conditions incident angle of the main beam becomes indetermination. Not only geometrical parameter 1Curve correction factor is affected by the angular distribution of the irradiation, thus varies by place. Not only geometrical parameter 2Uneven distribution of the solar irradiance due to curved surface, dynamic shading and partial shading Significant mismatching lossUnpredictable and complicated by string and variation of shape designsCombination of Graph theory and Monte Carlo simulation is investigated Design recommendation by the knowledge in the solar modeling. Relative to GHI, incl. curve-correction Rough estimation 1/3Power marginDepending on the driving zones latitude, climates, 20 power margin is recommended by the reduction of the effective irradiance on the car-roof. Rough estimation 2/3Urban drivingPartial shading probability mismatching loss substantially increases in the urban driving. Use of the cut cells thus increasing string number is inevitable. 1/2 cut, 4 strings 1/8 cut, 16 strings1/4 cut, 8 strings Rough estimation 3/3Partial shadings1/6 or more cut is recommended for suppressing partial-shading loss to 10. Lets study togetherAs resources increase, substantial greenhouse gas reduction will be achieved quickly.20 years ahead → 10 years ahead → 5 years aheadAcknowledgement A part of this research is based on NEDO entrusted research “research and development of ultrahigh efficiency · low cost III-V compound solar cell module“. I thank the people concerned.For this proposal, we received a hot discussions at various conferences. I am thankful to CPV guys and PV masters of high spirit.Regarding in-vehicle PV and peripheral technologies, I repeatedly discussed with Toyota Motor Corporation, Miyazaki University and Nagaoka University of Technology. Again thank you once again, next time I will delicious delicacies in Nagoya. 26
点击查看更多>>
收藏
下载该资源
京ICP备10028102号-1
电信与信息服务业务许可证:京ICP证120154号
地址:北京市大兴区亦庄经济开发区经海三路
天通泰科技金融谷 C座 16层 邮编:102600