切换
资源分类
文档管理
收藏夹
最新动态
登陆
注册
关闭
返回
下载
相似
相似资源:
非隔离T型三电平光伏逆变器关键控制技术研究_邢相洋
Growatt 逆变器常见故障排除
5kW-10kWh堆叠一体机实物接线分解图
20KW-30KWH三相堆叠一体机接线示意图
逆变器系列报告(1):新形势下MLPE赛道崛起,微型逆变器展望景气成长-东方证券.pdf
电力设备行业:三重渗透率递进,微型逆变器空间广阔-开源证券.pdf
第三讲 大型光伏并网电站的关键技术
光伏并网逆变器原理
逆变器基础
逆变器的原理.ppt
上能电气整县推进全场景逆变器解决方案.pdf
固德威智慧能源解决方案助推绿色未来
针对大硅片组件逆变器相关设计白皮书
SUN2000华为光伏逆变器运维培训材料
新能源发电的核心-逆变器的性能诊断
AMETEK 光伏逆变器测试解决方案-张龙
特变电工全新一代组串级逆变器解决方案-骆毅
PWM脉宽调制频率转模拟量电流电压4-20ma信号变送器
光伏组串I-V扫描与智能诊断技术白皮书
华为技术 - 迈向智能联接时代
1MW光伏电站逆变器侧设备清单及价格
资源描述:
Produkte Products Prü fbericht - Nr.Test Report No.15061668 001 Seite 2 von 26 Page 2 of 26TEST SUMMARY 4.1.1 H ARMONICS ON AC M AINSResultN/A4.1.2 V OLTAGE CHANGES , VOLTAGE FLUCTUATIONS AND FLICKER ON AC MAINSResultN/A4.1.3 M AINS T ERMINAL CONTINUOUS D ISTURBANCE VOLTAGEResultPassed4.2.1 RADIATED EMISSIONResultPassed5.1.1 ELECTROSTATIC D ISCHARGEResultPassed5.1.2 RADIO FREQUENCY ELECTROMAGNETIC FIELDResultPassed5.1.3 POWER FREQUENCY MAGNETIC FIELDSResultPassed5.2.1 ELECTRICAL FAST TRANSIENTS AND BURSTSResultPassed5.2.2 CONDUCTED DISTURBANCES , INDUCED BY RF FIELDSResultPassed5.2.2 SURGES TO AC POWER PORTResultPassed5.2.3 V OLTAGE DIPS AND INTERRUPTIONS TO AC POWER PORTResultN/AProdukte Products Prü fbericht - Nr.Test Report No.15061668 001 Seite 3 von 26 Page 3 of 26Contents 1 TEST SITES 41.1 TEST FACILITIES . 41.2 L IST OF TEST AND M EASUREMENT I NSTRUMENTS . 42 GENERAL PRODUCT INFORMATION 52.1 PRODUCT FUNCTION AND I NTENDED USE 52.2 RATINGS AND SYSTEM D ETAILS . 52.3 INDEPENDENT OPERATION M ODES. 52.4 N OISE GENERATING AND N OISE SUPPRESSING PARTS 52.5 SUBMITTED D OCUMENTS . 53 TEST SET-UP AND OPERATION MODES . 63.1 PRINCIPLE OF C ONFIGURATION SELECTION 63.2 PHYSICAL CONFIGURATION FOR T ESTING 63.3 TEST OPERATION AND T EST SOFTWARE . 63.4 SPECIAL A CCESSORIES AND AUXILIARY EQUIPMENT . 63.5 COUNTERMEASURES TO ACHIEVE EMC COMPLIANCE . 64 TEST RESULTS E M I S S I O N . 74.1 EMISSION IN THE FREQUENCY RANGE UP TO 30 MH Z 74.1.1 Harmonics on AC Mains . 74.1.2 Voltage changes, voltage fluctuations and flicker on AC mains . 74.1.3 Mains Terminal Continuous Disturbance Voltage . 84.2 EMISSION IN THE FREQUENCY RANGE ABOVE 30 MH Z 114.2.1 Radiated emission . 115 TEST RESULTS I M M U N I T Y 145.1 ENCLOSURE 155.1.1 Electrostatic Discharge 155.1.2 Radio Frequency Electromagnetic Field 165.1.3 Power frequency magnetic fields 175.2 INPUT DC PORT AND OUTPUT AC POWER PORTS. 185.2.1 Electrical fast transients and bursts 185.2.2 Conducted disturbances, induced by RF fields . 195.2.2 Surges to AC Power Port 205.2.3 Voltage dips and interruptions to AC Power Port 216 PHOTOGRAPHS OF THE TEST SET-UP 227 LIST OF TABLES . 268 LIST OF FIGURES . 269 LIST OF PHOTOGRAPHS . 26Produkte Products Prü fbericht - Nr.Test Report No.15061668 001 Seite 4 von 26 Page 4 of 261 Test Sites 1.1 Test Facilities Laboratory A T ü V Rheinland Shanghai Co., Ltd. Address B1-13F., No. 177, Lane 777 Guangzhong West Road, Zhabei District, Shanghai 200072, P.R. China Laboratory B Shanghai Electrical Appliance Testing Laboratory Address Room 44-8, No. 709, Ling Shi Road, Shanghai 200072 P.R. China The used test equipment is in accordance with CISPR 16-1 series standards for measurement of radio interference. The performed tests have been conducted by T ü V Rheinland ’ s engineer in lab. A or by “ Shanghai Testing Relative humidity 42 Expanded measurement uncertainty k2 3.58dB Test Setup Test voltage Input DC 520V; Output AC 230V, 50Hz Operational mode Continuously operated with power setting 4.6kW Earthing Through protective earth The measurement equipment like test receivers, quasi-peak detector and Artificial Mains Network AMN are in compliance with CISPR 16-1 series standards. The tested object was operated under its rated voltage and its rated frequency. Furthermore an internal calibration with the test receiver was conducted prior to each measurement. And the EUT was set 0.8m away from the AMN. The following figures and tables were those measured by an automatic measuring system. Both Quasi-Peak and Average Value were measured. Quasi-Peak and Average Value were measured and listed respectively where they had a maximum in previous scanning survey. In the Figures, “ blue ” means Quasi-Peak Value and “ green ” means Average Value which was measured in final measurement. Produkte Products Prü fbericht - Nr.Test Report No.15061668 001 Seite 9 von 26 Page 9 of 26Figure 1 Spectral Diagrams, conducted emission, 150kHz - 30MHz, L Level [dB μ V] Final quasi-peak measurement results Frequency MHz QuasiPeak dB μ V Meas. Time ms Bandwidth kHz Line Corr. dB Margin dB Limit dB μ V 0.162000 61.2 1000.000 9.000 L1 10.1 4.1 65.3 0.586000 44.5 1000.000 9.000 L1 10.1 11.5 56.0 0.666000 43.7 1000.000 9.000 L1 10.1 12.3 56.0 0.746000 42.5 1000.000 9.000 L1 10.1 13.5 56.0 18.642000 48.4 1000.000 9.000 L1 10.2 11.6 60.0 26.838000 46.9 1000.000 9.000 L1 10.6 13.1 60.0 Final average measurement results Frequency MHz CAverage dB μ V Meas. Time ms Bandwidth kHz Line Corr. dB Margin dB Limit dB μ V 0.162000 52.9 1000.000 9.000 L1 10.1 2.4 55.3 0.178000 49.9 1000.000 9.000 L1 10.1 4.6 54.5 0.210000 47.6 1000.000 9.000 L1 10.1 5.4 53.0 0.398000 42.2 1000.000 9.000 L1 10.1 5.5 47.7 0.506000 41.5 1000.000 9.000 L1 10.1 4.5 46.0 0.586000 41.0 1000.000 9.000 L1 10.1 5.0 46.0 Produkte Products Prü fbericht - Nr.Test Report No.15061668 001 Seite 10 von 26 Page 10 of 26Figure 2 Spectral Diagrams, conducted emission, 150kHz - 30MHz, N Level [dB μ V] Final quasi-peak measurement results Frequency MHz QuasiPeak dB μ V Meas. Time ms Bandwidth kHz Line Corr. dB Margin dB Limit dB μ V 0.162000 60.0 1000.000 9.000 N 10.1 5.3 65.3 0.426000 44.3 1000.000 9.000 N 10.1 12.9 57.2 0.582000 43.3 1000.000 9.000 N 10.1 12.7 56.0 2.890000 41.9 1000.000 9.000 N 10.1 14.1 56.0 18.530000 55.3 1000.000 9.000 N 10.2 4.7 60.0 24.918000 52.5 1000.000 9.000 N 10.2 7.5 60.0 Final average measurement results Frequency MHz CAverage dB μ V Meas. Time ms Bandwidth kHz Line Corr. dB Margin dB Limit dB μ V 0.162000 52.2 1000.000 9.000 N 10.1 3.1 55.3 0.174000 49.2 1000.000 9.000 N 10.1 5.5 54.7 0.398000 41.9 1000.000 9.000 N 10.1 5.8 47.7 0.502000 39.3 1000.000 9.000 N 10.1 6.7 46.0 18.374000 48.3 1000.000 9.000 N 10.2 1.7 50.0 25.246000 45.5 1000.000 9.000 N 10.2 4.5 50.0 Produkte Products Prü fbericht - Nr.Test Report No.15061668 001 Seite 11 von 26 Page 11 of 264.2 Emission in the Frequency Range above 30 MHz 4.2.1 Radiated emission Result Passed Date of testing 14.09.2012 Test procedure EN 61000-6-32007A1 and CISPR 16 series standards Frequency range 30 - 1000MHz Limits Table clause 1.1 of table 1 of EN 61000-6-32007A1 Quasi-peak limits 3m measurement distance 30-230MHz, 40dB μ V/m; 230-1000MHz, 47dB μ V/m Kind of test site Semi-anechoic Chamber Test distance 3m Operation mode Continuously operated with load 4.6kW Ambient condition Temperature 23.7oC; Relative humidity 50 The radiated disturbance was measured in the frequency range from 30MHz to 1000MHz according to EN 61000-6-32007A1. The test setup was made according to EN 61000-6-32007A1 in a semi-anechoic chamber. The test distance from the receiving antenna to the EUT is 3m. The normalized site attenuation of the semi-anechoic chamber is regularly calibrated to ensure the radiated disturbance test results are valid. During the test, the EUT was placed on the turntable. The turntable can be rotated 360o around and the receiving antenna was varied from 1m to 4m to find the maximum disturbance. The test was performed with the antenna both in horizontal and vertical polarizations. The following figures were those measured and recorded by a test receiver. The curves in the figure were those measured with a peak detector. The symbol “ ” in the figures are those of quasi-peak value which were measured in final measurement. Quasi-peak detector measurement was only performed at those critical frequencies obtained during the test with peak detector. Produkte Products Prü fbericht - Nr.Test Report No.15061668 001 Seite 12 von 26 Page 12 of 26Figure 3 Spectral diagram and measurement results, Horizontal polarization Level [dB μ V/m] Final measurement results Frequency MHz QuasiPeak dBμ V/m Meas. Time ms Bandwidth kHz Height cm Polarization Azimuth deg Corr. dB Margin dB Limit dBμ V/m 31.503500 17.6 1000.0 120.000 100.0 H 91.0 19.2 22.4 40.0 43.822500 10.5 1000.0 120.000 100.0 H 91.0 12.6 29.5 40.0 932.682000 27.8 1000.0 120.000 100.0 H 91.0 26.6 19.2 47.0 Produkte Products Prü fbericht - Nr.Test Report No.15061668 001 Seite 13 von 26 Page 13 of 26Figure 4 Spectral diagrams and measurement results, Vertical polarization Level [dB μ V/m] Final measurement results Frequency MHz QuasiPeak dBμ V/m Meas. Time ms Bandwidth kHz Height cm Polarization Azimuth deg Corr. dB Margin dB Limit dBμ V/m 33.589000 37.9 1000.0 120.000 246.0 V 91.0 18.2 2.1 40.0 35.335000 37.7 1000.0 120.000 180.0 V 91.0 17.2 2.3 40.0 37.760000 38.0 1000.0 120.000 100.0 V 91.0 15.9 2.0 40.0 38.196500 37.2 1000.0 120.000 100.0 V 91.0 15.7 2.8 40.0 Produkte Products Prü fbericht - Nr.Test Report No.15061668 001 Seite 14 von 26 Page 14 of 265 Test Results I M M U N I T Y During the immunity tests, the EUT was operated under conditions specified by clause 3.1 of this report. The particular performance criterion for the immunity tests are as listed in clause 4 of EN 61000-6-22005 is listed as follows Performance criterion A The apparatus shall continue to operate as intended during and after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of those may be derived from the product description and documentation, and from what the user may reasonably expect from apparatus if used as intended. Performance criterion B The apparatus shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. No change of actual operating state or stored data is allowed. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of those may be derived from the product description and documentation and what the user may reasonably expect from the apparatus if used as intended. Performance criterion C Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by the operation of the controls. Produkte Products Prü fbericht - Nr.Test Report No.15061668 001 Seite 15 von 26 Page 15 of 265.1 Enclosure 5.1.1 Electrostatic Discharge Result Passed During the test, the EUT was placed on 0.8m high wooden table above the ground plane. The minimum distance between the EUT and all other conductive structures except the ground plane beneath the EUT is more than 0.5m. The size of the reference ground plane is more than 2m by 2m. A horizontal coupling plane HCP, 1.6m x 0.8m, placed on the table and isolate the EUT 0.5mm thick. Vertical coupling plane of dimensions 0.5m x 0.5m is placed parallel to and positioned at a distance of 0.1m from the EUT. Date of testing 12.12.2012 Test procedure IEC 61000-4-2 Test level Table 1 of EN 61000-6-22005 ± 2.0kV, ± 4.0kV contact discharge; ± 2.0kV, ± 4.0kV, ± 8.0kV air discharge Polarity Positive / Negative Number of discharges 10 at each point Performance criteria B Operating mode Continuously operated with low power setting Ambient condition Temperature 21.5 ° C, Relative humidity 50.1 Table 2 Electrostatic discharge immunity test results Position Kind of Discharge Remarks Plastic enclosure, seam Air discharge During and after the test, the EUT can operate as intended. Power line Air discharge Ditto Display Air discharge Ditto Metallic part Contact discharge Ditto Button Air discharge Ditto HCP 1.4-2.0GHz, 3V/m; 2.0-2.7GHz, 1V/m Frequency range 80-1000MHz, 1.4-2.7GHz Modulation 80AM, 1kHz Frequency scan speed Frequency step 1; Dwell time 3s Performance criteria A Operating mode Continuously operated with low power setting Ambient condition Temperature 23.7 ° C, Relative humidity 50 Table 3 Radiated electromagnetic field test results Field polarization Side Observation Remarks Horizontal polarization Front No disturbance of function Passed Rear Left Right Vertical polarization Front Ditto Passed Rear Left Right Produkte Products Prü fbericht - Nr.Test Report No.15061668 001 Seite 17 von 26 Page 17 of 265.1.3 Power frequency magnetic fields Result Passed Testing according to IEC 61000-4-8 is usual where components sensitive to magnetic field are used. Grid connected inverter frequently use Hall effect current sensors. However, these sensors are designed to operate in locations where high levels of magnetic fields exist close vicinity of power conductors. Those amplitudes are much higher than the levels of the test according to IEC 61000-4-8. It can therefore be considered that the disturbance applied by the test is negligible compared to the operating environment of this sensitive component. Therefore, the sample is deemed to meet the requirements of IEC 61000-4-8 without actual testing. Produkte Products Prü fbericht - Nr.Test Report No.15061668 001 Seite 18 von 26 Page 18 of 265.2 Input DC port and Output AC Power Ports 5.2.1 Electrical fast transients and bursts Result Passed The test generator and coupling and decoupling device was directly put on the reference ground plane. The length between the coupling device and the EUT is less than 0.5m. The excess length of the cable shall be folded to avoid a flat coil and situated at a distance of 0.1m above the ground reference plane. For the AC power output port, the disturbing signal was coupled via a CDN; for the DC power input port, the disturbing signal was coupled via a capacitive clamp. The reference ground plane is an aluminum sheet of 0.25mm minimum thickness. The reference ground plane is connected to the protective earth. Date of testing 12.12.2012 Test procedure IEC 61000-4-4 Test level Table 3, 4 of EN 61000-6-22005 ± 0.5kV, ± 1kV, ± 2kV, 5kHz, for DC input port; ± 0.5kV, ± 1kV, ± 2kV, 5kHz, for AC output port; Polarity /- Coupling duration 1 min/polarity Performance criteria B Operating mode Continuously operated with low power setting Ambient condition Temperature 21.3 ° C, Relative humidity 42 Table 4 EFT/B immunity test results Tested cable Result Remarks AC output port LNPE-GRP Pass During and after the test, the EUT can operate as intended. DC input port Pass Ditto Produkte Products Prü fbericht - Nr.Test Report No.15061668 001 Seite 19 von 26 Page 19 of 265.2.2 Conducted disturbances, induced by RF fields Result Passed For the AC output port, the disturbing signal was coupled via a CDN. For the DC input port, the disturbing s
点击查看更多>>
收藏
下载该资源
京ICP备10028102号-1
电信与信息服务业务许可证:京ICP证120154号
地址:北京市大兴区亦庄经济开发区经海三路
天通泰科技金融谷 C座 16层 邮编:102600