切换
资源分类
文档管理
收藏夹
最新动态
登陆
注册
关闭
返回
下载
相似
相似资源:
非隔离T型三电平光伏逆变器关键控制技术研究_邢相洋
Growatt 逆变器常见故障排除
5kW-10kWh堆叠一体机实物接线分解图
20KW-30KWH三相堆叠一体机接线示意图
逆变器系列报告(1):新形势下MLPE赛道崛起,微型逆变器展望景气成长-东方证券.pdf
电力设备行业:三重渗透率递进,微型逆变器空间广阔-开源证券.pdf
第三讲 大型光伏并网电站的关键技术
光伏并网逆变器原理
逆变器基础
逆变器的原理.ppt
上能电气整县推进全场景逆变器解决方案.pdf
固德威智慧能源解决方案助推绿色未来
针对大硅片组件逆变器相关设计白皮书
SUN2000华为光伏逆变器运维培训材料
新能源发电的核心-逆变器的性能诊断
AMETEK 光伏逆变器测试解决方案-张龙
特变电工全新一代组串级逆变器解决方案-骆毅
PWM脉宽调制频率转模拟量电流电压4-20ma信号变送器
光伏组串I-V扫描与智能诊断技术白皮书
华为技术 - 迈向智能联接时代
1MW光伏电站逆变器侧设备清单及价格
资源描述:
北美市场逆变器安规要求2016/2/29 1. AFCI 故障电弧断路器 NEC 690.11 Arc-Fault Circuit Protection Direct Current. 直流侧故障电弧保护电路Photovoltaic systems with dc source circuits, dc output circuits,or both, operating at a PV system maximum system voltage of 80 volts or greater, shall be protected by a listed dc arc-fault circuit interrupter, PV type, or other system components listed to provide equivalent protection. The PV arc-fault protection means shall comply with the following requirements 1 The system shall detect and interrupt arcing faults resulting from a failure in the intended continuity of a conductor, connection, module, or other system component in the dc PV source and dc PV output circuits. 2 The system shall require that the disabled or disconnected equipment be manually restarted. 3 The system shall have an annunciator that provides a visual indication that the circuit interrupter has operated.This indication shall not reset automatically.带有直流输入电路, 或者直流输出电路, 或者两者都有的光伏系统, 且工作在 80V 或者更高的光伏系统电压时, 要么有列出过的直流故障电弧断路装置, 要么有光伏类型的或者其他列出的系统组件来提供等效的保护。这些光伏故障电弧保护装置必须满足以下几点1 系统必须能检测到正在发生的故障电弧并断开系统的直流输入和直流输出电路。2 系统要让已经关闭的或者断开的设备人为的重新启动。3 系统必须有一个可视化的报警信号,表示故障电弧断路器已经工作了,并且这个报警信号不能自动关闭。2. RSD快速关断 NEC 690.12 Rapid Shutdown of PV Systems on Buildings. 屋顶光伏系统的快速关断PV system circuits installed on or in buildings shall include a rapid shutdown function that controls specific conductors in accordance with 690.121 through 5 as follows. 1 Requirements for controlled conductors shall apply only to PV system conductors of more than 1.5 m 5 ft in length inside a building, or more than 3 m 10 ft from a PV array. 2 Controlled conductors shall be limited to not more than 30 volts and 240 volt-amperes within 10 seconds of rapid shutdown initiation. 3 V oltage and power shall be measured between any two conductors and between any conductor and ground. 4 The rapid shutdown initiation methods shall be labeled in accordance with 690.56B. 5 Equipment that performs the rapid shutdown shall be listed and identified.安装在屋顶或者室内的光伏系统必须有快速关断的功能, 快速关断是通过控制特定开关实现的,必须满足以下几点1 受控开关安装在光伏板一定的距离内,如果开关在室内,此距离是 1.5 米 5 英尺 ,如果安装在室外,此距离是 3 米 10 英尺 。2 当快速关断启动后的 10 秒内,受控开关必须保证其输出电压小于 30V 且输出功率小于240VA。3 上述输出电压和功率代表任意两个开关输出端或者单个开关对地的值。4 快速关断旁边必须打上标签,且标签满足 690.56B 的规范。5 用作快速关断的设备必须是上市的或者认证过的。
点击查看更多>>
收藏
下载该资源
京ICP备10028102号-1
电信与信息服务业务许可证:京ICP证120154号
地址:北京市大兴区亦庄经济开发区经海三路
天通泰科技金融谷 C座 16层 邮编:102600