切换
资源分类
文档管理
收藏夹
最新动态
登陆
注册
关闭
返回
下载
相似
相似资源:
分布式能源及独立微网容量配置与运行优化研究
清华AI研究院-区块链发展研究报告2020
20-07_Braid_PVPMC_sm3
Ransome_PVPMC_webinar_20_08_05
Schneider_PVPMC_Webinar_2020-08-05_Solargis
Prilliman_PVPMC_webinar_2020-08-05
UL_MultipleSatelliteModelsMCP_2020-06-18_Slides
Sengupta-NREL-NSRDB_Status-PVPMC-Webinar
GroundWork-PVPMC-2020-06-22-Slides
PVMPC-Clean-Power-Research-Data-Sources-and-Validation-24062020
PVPMC_Webinar_Martin_Herrerias
BIPV建筑光伏一体化产品与解决方案
《PVsyst 6 中文手册》2019.03.12
遮光物体对双面组件能量收益率影响的模型-朱强忠-隆基
基于人工神经网络的双面光伏系统设计研究-韩利生-苏州中来光伏新材股份有限公司
环境因素对光伏工程发电影响的研究-惠星-西北勘测设计研究院有限公司
晶体硅光伏组件在服役过程中功率损失的理论计算与数值模拟研究-董娴-中山大学
基于SCADA数据的光伏系统故障诊断与分类-赵莹莹-协合新能源集团有限公司
应用光线追踪方法建模双面电站系统 范例与验证-薄中南 Jefferson Bor-Fraunhofer ISE
光伏组件清洗机器人改善光伏电站发电性能的研究-王军-上海安轩自动化科技有限公司
光伏阵列的平面太阳能辐照度和辐射计算-王斯成-国家发改委能源研究所
资源描述:
P R E S E N T E D B Y Sandia National Laboratories is a multimission laboratory managed and operated by National Technology day-to-day and site-to-site variability increase uncertainty in these differencesAOI q Introduction5 In this presentation, we explore a differential method for visualizing and quantifying the differences in the reflective AOI properties of several modules and the potential impact on system power Several commercial utility grade modules and a module with an experimental ARC are used to demonstrate the method A key point, all testing was performed simultaneously, making direct comparisons possibleMFG Model PSEL ID First Solar FS4 No ARC 3262First Solar FS4 non-prod ARC 1 3261JA Solar JAM6k-72-4BB 345W 3268Yingli YL330P-35b 3267 AOI q Test Method Outdoor Angle of Incidence Characterization Method7 Equipment Azimuth-Elevation solar tracker capable of rotating the test plane to solar incident angles between 0° and 90° Global Pyranometer in the test plane measuring diffuse POA irradiance Ediff Pyrheliometer on a separate weather tracker measuring Direct Normal Irradiance E DNI Current-Voltage IV sweep system Module temperature measurement systemEnvironmental Conditions High Irradiance, low diffuse Low variation in Irradiance during test Low wind speed/changes in ambient temperature during test Bruce H. King, Clifford W. Hansen, Dan Riley, Charles D. Robinson, Larry Pratt, “Procedure to Determine Coefficients for the Sandia Array Performance Model SAPM,” SAND2016-5284, Sandia National Laboratories, Albuquerque, NM, 2016. 0° 5° 10° 15° 20° 25° 30° 35°40° 44° 48° 52° 56° 60° 64° 67°70° 73° 76° 79° 82° 85° 87° 89°Typical Incident Angles Outdoor Angle of Incidence Characterization Method8 Procedure Initiate IV scans, 2 scans/minute typical Hold module normal to the Sun for a minimum of 10 minutes. Ensure Short Circuit Current Isc is stable Index tracker off sun Dwell for several minutes at each AOI, collect 4-5 IV curves per condition. Analysis9 Correct measured Isc for temperature and spectrum Find reference Iscr at AOI 0° Find normalized I sc Nisc Plot Nisc vs AOI to visualize function, f2q Test Results and Differential Analysis Results – Standard Reporting11 All modules relatively flat pure cosine response out to 55° Minor apparent differences beyond 55° Yingli and First Solar ARC1 appear to be similar and consistently outperform all other modules commercial modules Performance assessment is typically visual and subjective “better” or “worse” New Approach to Quantifying Performance – Differential Analysis12 Determine simple differential between test device and a reference For this example, we use a plain glass module with no ARC Reference and test device must be measured simultaneously to eliminate differing environmental conditions between tests Resulting differential is independent of diffuse light and only dependent on DNI Differential Analysis - Examples13 Examples for two commercial modules and a First Solar module with experimental ARC Divergence from plain glass behavior can be seen as low as 30° All modules showed a boost at higher AOI. Degree of boost appears to be correlated with peak q. Differential for commercial modules went negative at high AOI. Differential for one module showed a dip at intermediate AOI, 35°. Application to PV System Performance Application to PV System Performance15 Goals Demonstrate applicability of differential analysis to simulate differences in system performance Apply for multiple modules, multiple system configurationsSystems Fixed Tilt 35°, Fixed Tilt 10°, single axis tracker SAT Modules JA Solar, Yingli, First Solar Non-Production ARC1Inputs 2017 weather from on-site weather station at Sandia Albuquerque, NM High temporal resolution, 1 minute samples f2q, Df2q for each module from simultaneous outdoor testing Modeling Steps16 Determine AOI q for each time step, each system orientationpvl_getaoi.m, pvl_singleaxis.m Calculate diffuse irradiance for each AOI only used for gain calculationspvl_haydavies1980.m, pvl_extraradiation.m Determine Df 2q for each time step, each system orientationlookup table with spline interpolation Calculate Net Irradiance difference, Net Irradiance for plain glass module Determine Daily Average Difference in Net Irradiance Determine Daily Difference in Irradiance, compared to plain glass directly comparable to power gain or loss Difference in Net Irradiance17 Results are normalized for length of day – reveal seasonal differences that are dependent on AOI only Performance differences can clearly be seen, both between modules and systems For 35° Tilt, gains for the two modules with the most pronounced differential are seasonally flat For both 10° Tilt and Single Axis Tracker, gains for these same two modules show strong seasonality better relative performance in Winter Difference, Relative to Plain Glass18 Results are totaled for each day, includes seasonal differences due to length of day Performance differences relative to the reference module plain glass can be quantified For 35° Tilt, modules with seasonally flat gains in differential provide a higher gain in summer due to longer day For both 10° Tilt and Single Axis Tracker, seasonal gains are more pronounced. For 10° Tilt, Winter gains up to 1 are observed. Annual Gain19 Module Orientation35° Tilt 10° Tilt SATJA Solar 0.02 0.04 0.03Yingli 0.33 0.44 0.16First Solar ARC1 0.33 0.46 0.10Annual Gain in Effective Irradiance Annual gains approaching 0.5 were highest for 10° Tilt orientation Annual gains were modest for Single Axis Tracker Module with lowest differential response showed negligible annual gains in any orientation Summary20 Differential Analysis is an effective approach to visualize and quantify the effectiveness of ARCs at non-normal incidence angles “Better” performing modules show minimal differential response at low incidence angles and strong peaks at higher angles “Weaker” modules may show dips in response at lower angles. This may negate gains seen at higher angles. Differential Analysis can be extended to demonstrate effectiveness of different ARCs in different deployment scenarios Of the scenarios investigated, 10° Fixed Tilt benefitted the most from good ARCs and Single Axis Trackers benefitted the least. Reminder Gains or losses in Incident Angle response due to an ARC are IN ADDITION TO gains in normal transmission 21 Thank Youbhkingsandia.gov
点击查看更多>>
收藏
下载该资源
京ICP备10028102号-1
电信与信息服务业务许可证:京ICP证120154号
地址:北京市大兴区亦庄经济开发区经海三路
天通泰科技金融谷 C座 16层 邮编:102600