返回 相似
资源描述:
1 中国水发兴业能源集团有限公司 China Shuifa Singyes Energy Holdings Limited 中国水发兴业能源集团研究院 珠海中建兴业绿色建筑设计研究院罗多LUODUO 2 3.1 Building-integrated photovoltaic system BIPV system A BIPV system is a photovoltaic system in which the PV modules satisfy the definition of IEC 63092-1 for BIPV modules. It includes the electrical components needed to connect the PV modules to external AC or DC circuits and the mechanical mounting systems needed to integrate the BIPV modules into the building. BIPV系统是指光伏组件满足IEC 63092 -1对BIPV组件的定义的光伏系统。它包括将光伏组件连接到外部交流或直流电路所需的电子元件,以及将BIPV组件集成到建筑中所需的机械安装系统。3.2 Building-integrated photovoltaic module – BIPV module Photovoltaic module that provides one or more of the functions of the building envelope. 为建筑围护结构提供一个或多个功能的光伏组件 NOTE The building envelope functions shall be, depending on the application, one or more of the following a Mechanical rigidity or structural integrity (机械刚性或结构完整性)b Primary weather impact protection rain, snow, wind, hail (主要天气影响防护雨、雪、风、雹)c Shading, daylighting, thermal insulation (遮阳,采光,保温)d Fire protection (消防) e Noise protection (隔音)f Separation between indoor and outdoor environments (隔绝室内外环境)g Security, shelter or safety (防护,庇护或安全) NOTE If a BIPV module is uninstalled, it would have to be replaced by an appropriate building product. (注意如果要卸载一个BIPV组件,则必须用适当的建筑产品替换它)2.0.6 建筑集成光伏发电系统 Building-integrated photovoltaic ( BIPV ) 光伏发电设备作为建筑材料或构件,在建筑上应用的形式,也成光伏建筑一体化 3 检测项目检测方法检测目的 光伏幕墙光伏采光顶 抗风压性能GB/T 15227 ----安全性结构性能---- GB/T 34555安全性水密性能GB/T 15227 GB/T 34555适用性气密性能GB/T 15227 GB/T 34555节能性层间变形性能GB/T 18250 ---安全性抗震性能GB/T 18575 GB/T 18575安全性抗风携碎物冲击性能GB/T 29738 GB/T 29738安全性保温性能 GB/T 29043参照GB/T 29043节能性隔热性能 JGJ/T 151 JGJ/T 151节能性空气声隔声性能GB/T 8485 GB/T 8485适用性光热性能GB/T 18091 GB/T 18091节能性 热循环性能JG/T 397 JG/T 397耐久性检测光伏采光顶的结构性能时,考虑可能出现的积水荷载、雪荷载、冰荷载和其他特殊荷载。检测项目检测方法检测目的 光伏幕墙光伏采光顶 可开启部分启闭力GB/T 9158 GB/T 9158适用性耐撞击性能GB/T 21086 ---安全性抗冲击性能--- JG/T 231安全性 检测项目检测方法检测目的 光伏幕墙光伏采光顶 电致发光检测5.4.2效率最大功率IEC612152005IEC616462008效率绝缘耐压IEC612152005IEC616462008安全性湿漏电流IEC612152005IEC616462008安全性湿冻试验IEC612152005IEC616462008效率 4电 气 性 能 检 测 流 程 图Electrial properties test tree最大输出功率的衰减不超过试验前测试值的5The attenuation of the maximum output power isless than 5 of the test value before the test . 最不利环境试验The most unfavorable environment test结构安全实验Structure safety test电气安全试验The most unfavorable environment test 5 测 试方 法电气性能安全*最大功率*绝缘耐压*湿漏电流 *EL检 测光伏幕墙建筑物理性能 *抗压性 *水密*气密 *层间变形复检电气性能安装试件Install the specimen拆卸试件Remove thespecimen根据测试方法模型,为了确定电池片隐裂与风压的内在关联,扩展出本次循环测试 This loop test helps to confirm the invisible crack in cell has innerconnection with wind pressure.*最大功率*绝缘耐压*湿漏电流 *EL检 测 Electrial properties safetyRecheck the electrial properties Phsicial properties 6 循环测试步骤Procedure分项 Contents对应荷载Load对应变形Deformation对应挠度Deflection初始测试Initial test光伏组件耐压绝缘测试 Insulation voltage withstand test光伏组件IV测试 IV test光伏组件EL测试(隐裂测试)EL test invisible crack test第一轮测试First round test光伏幕墙抗风压性能测试 Anti-wind pressure performance test 1.02kN/㎡ 7.41 mm 1/160光伏组件IV测试 IV test光伏组件EL测试(隐裂测试)EL test invisible crack test第二轮测试Second round test光伏幕墙抗风压性能测试 Anti-wind pressure performance test 1.35kN/㎡ 8.73 mm 1/120光伏组件IV测试 IV test光伏组件EL测试(隐裂测试) EL test invisible crack test第三轮测试Third round test光伏幕墙抗风压性能测试 Anti-wind pressure performance test 2.1kN/㎡ 11.71 mm 1/90光伏组件IV测试 IV test光伏组件EL测试(隐裂测试) EL test invisible crack test第四轮测试Fourth round test光伏幕墙抗风压性能测试 Anti-wind pressure performance test 2.73kN/㎡ 16.77 mm 1/60光伏组件IV测试 IV test光伏组件EL测试(隐裂测试) EL test invisible crack test Procedure of test 7 数据分析试件01 specimen 01试件02specimen 02试件03 specimen 03试件04specimen 04 8Ø光 伏 幕 墙 建 筑 物 理 性 能 与 电 气 性 能 存 在 一 定 的 联 系 , 在 进 行 评 价 时 不 能 单 独 进 行 。While in evaluation ,physical properties and electrical properties can t be seperated.Ø排 除 光 伏 组 件 在 施 工 、 搬 运 造 成 的 影 响 后 , 光 伏 组 件 在 承 受 风 压 后 依 然 出 现 隐 裂 , 推 导 出 组 件 在 受 到 风 压 影 响后 会 产 生 隐 裂 的 可 能 。PV modules may produce invisible crack after affected by wind pressure.Ø光 伏 组 件 的 IV性 能 在 数 次 风 压 测 试 后 无 明 显 变 化 , 推 导 是 因 为 隐 裂 对 光 伏 组 件 产 生 的 影 响 不 是 立 竿 见 影 的 , 而是 一 个 缓 慢 发 生 的 结 果 , 不 能 在 短 期 内 检 测 出 结 果 。It couldn t get the result in a short time for the impact on PV modules is really gradual. IV performance change 9 1、参考了46本标准,其中IEC26本,ISO20本。正文中还引用了7本包括欧标在内的其他标准;2、IEC多数为电气方面的标准,ISO多数为建筑方面的标准;3、应用的标准多为技术要求、检测方法、计算方法、评价方法、术语等;4、本标准主要工作就是分类,再根据分类提出相关的参考标准的要求;1、编写标准的角度不同国际标准侧重于“买方”的角度,国内标准侧重于“卖方”的角度;2、编写标准的目的不同国际标准只提要求,重结果,国内标准希望 步步为营、越细越好;3、编写标准的方法不同;国际标准只有产品标准和设计指导,国内标准既有产标也有工标,工标几乎涵盖工程建设、运营的全阶段。4、本标准主要工作就是分类,再根据分类提出相关的参考标准的要求,需要对几十本标准熟悉,如何采用 1.夹胶光伏构件的各层玻璃如作为结构受力构件参与结构计算时,各层单片玻璃厚度差不宜大于3mm。【条文说明】无论是两层还是三层的夹胶光伏构件,各层玻璃如共同受力参与结构计算,厚度相差过大,则两片玻璃受力不均匀,容易产生破裂。但是如果某一层玻璃不参与受力计算,如6T0.76PVB2T钢化夹胶玻璃,所有荷载均由6mm钢化玻璃承担,2mm钢化玻璃仅视为一层保护膜不参与结构计算,则可以不考虑“厚度差3mm”的要求,又如8T1.14PVB3.21.14PVB8T钢化夹胶玻璃,中间的3.2mm玻璃为薄膜电池的芯片,不钢化,不参与受力,同样为设计合理的光伏构件。 2.单层玻璃夹胶光伏构件的玻璃厚度不宜小于5mm。【条文说明】单层玻璃夹胶光伏构件的结构构成通常为玻璃EVAPVEVA光伏背膜,由于多了两层胶片,使得该结构的抗冲击性能(软物冲击和硬物冲击)增加,满足安全玻璃的要求,而该类构件必须采用有边框的设计,这就避免了裸边玻璃在运输安装过程中小于6mm情况下容易破损的问题。因此,单层玻璃夹胶光伏构件的最小玻璃厚度定为5mm。 10
点击查看更多>>

京ICP备10028102号-1
电信与信息服务业务许可证:京ICP证120154号

地址:北京市大兴区亦庄经济开发区经海三路
天通泰科技金融谷 C座 16层 邮编:102600